Skip to content
Fencer Vulns
high 8.6

CVE-2022-1118 in the critical feed json

Rockwell Automation ISaGRAF Deserialization of Untrusted Data

published 2022-05-17 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-24461

cvss
8.6
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
11.1%
EPSS 11.1% chance of exploitation in 30 days, percentile 95%
public exploits
0
none known

Summary

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-22-095-01 updated cvss 8.6

Rockwell Automation ISaGRAF

  • Rockwell Automation Connected Component Workbench <= 13.00.00 Rockwell Automation ISaGRAF Workbench >=6.0, <= 6.6.9 Rockwell Automation Safety Instrumented Systems Workstation <= 1.2 (for Trusted Controllers)
    affected: vendor fix, mitigation “Rockwell Automation encourages users to update to v20.00 or later.” compatibility.rockwellautomation.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
18 mo ago

Exploit prediction

11.10% chance of exploitation in the next 30 days, higher than 95% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 8.6 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
NVD 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVD 2.0 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P

Affected products

  • Rockwell Automation Connected Component Workbench
  • Rockwell Automation ISaGRAF Workbench
  • Rockwell Automation Safety Instrumented Systems Workstation

Classification

Weakness
  • CWE-502 Deserialization of Untrusted Data

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.