CVE-2022-0715 json

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a k…

published 2022-03-09 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-15790

cvss
8.9
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
6.0%
EPSS 6.0% chance of exploitation in 30 days, percentile 93%
public exploits
0
none known

Summary

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
5 mo ago

Exploit prediction

5.96% chance of exploitation in the next 30 days, higher than 93% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CISA ADP 3.1 8.9 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H
NVD 3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
CNA 3.1 8.9 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H
NVD 2.0 6.4 AV:N/AC:L/Au:N/C:N/I:P/A:P

Affected products

  • Schneider Electric APC Smart-UPS
  • Schneider Electric SmartConnect

Classification

Weakness
  • CWE-287 Improper Authentication
  • CWE-345 Insufficient Verification of Data Authenticity