Skip to content
Fencer Vulns
high 8.2

CVE-2021-45970 json

An issue was discovered in IdeBusDxe in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 bef…

published 2022-01-05 4 y ago modified 2026-08-11 2 mo ago also EUVD-2021-32676

cvss
8.2
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 28%
public exploits
0
none known

Summary

An issue was discovered in IdeBusDxe in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (the status code saved at the CommBuffer+4 location).

Patch / fix

  • Siemens RUGGEDCOM APE1808 - BIOS V1.0.202N
  • Siemens SIMATIC Field PG M5 V22.01.10
  • Siemens SIMATIC Field PG M6 V26.01.13
  • Siemens SIMATIC IPC127E V27.01.09
  • Siemens SIMATIC IPC227G V28.01.04
  • Siemens SIMATIC IPC277G V28.01.04
  • Siemens SIMATIC IPC277G PRO V28.01.04
  • Siemens SIMATIC IPC327G V28.01.04
  • Siemens SIMATIC IPC377G V28.01.04
  • Siemens SIMATIC IPC427E V21.01.17
  • Siemens SIMATIC IPC477E V21.01.17
  • Siemens SIMATIC IPC477E PRO V21.01.17
  • Siemens SIMATIC IPC627E V25.02.12
  • Siemens SIMATIC IPC647E V25.02.12
  • Siemens SIMATIC IPC677E V25.02.12
  • Siemens SIMATIC IPC847E V25.02.12
  • Siemens SIMATIC ITP1000 V23.01.10
  • Siemens SIPLUS IPC427E V21.01.17

Exploit prediction

0.35% chance of exploitation in the next 30 days, higher than 28% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 8.2 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
NVD 2.0 7.2 AV:L/AC:L/Au:N/C:C/I:C/A:C

Affected products

  • Siemens RUGGEDCOM APE1808 - BIOS
  • Siemens SIMATIC Field PG M5
  • Siemens SIMATIC Field PG M6
  • Siemens SIMATIC IPC127E
  • Siemens SIMATIC IPC227G
  • Siemens SIMATIC IPC277G
  • Siemens SIMATIC IPC277G PRO
  • Siemens SIMATIC IPC327G
  • Siemens SIMATIC IPC377G
  • Siemens SIMATIC IPC427E
  • Siemens SIMATIC IPC477E
  • Siemens SIMATIC IPC477E PRO
  • Siemens SIMATIC IPC627E
  • Siemens SIMATIC IPC647E
  • Siemens SIMATIC IPC677E
  • Siemens SIMATIC IPC847E
  • Siemens SIMATIC ITP1000
  • Siemens SIPLUS IPC427E

Classification

Weakness

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.