Skip to content
Fencer Vulns
high 8.2

CVE-2021-43615 json

An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 b…

published 2022-02-03 4 y ago modified 2026-08-11 2 mo ago also EUVD-2021-30529

cvss
8.2
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 21%
public exploits
0
none known

Summary

An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Patch / fix

  • Siemens RUGGEDCOM APE1808 - BIOS V1.0.202N
  • Siemens SIMATIC Field PG M5 V22.01.10
  • Siemens SIMATIC Field PG M6 V26.01.13
  • Siemens SIMATIC IPC127E V27.01.09
  • Siemens SIMATIC IPC227G V28.01.04
  • Siemens SIMATIC IPC277G V28.01.04
  • Siemens SIMATIC IPC277G PRO V28.01.04
  • Siemens SIMATIC IPC327G V28.01.04
  • Siemens SIMATIC IPC377G V28.01.04
  • Siemens SIMATIC IPC427E V21.01.17
  • Siemens SIMATIC IPC477E V21.01.17
  • Siemens SIMATIC IPC477E PRO V21.01.17
  • Siemens SIMATIC IPC627E V25.02.12
  • Siemens SIMATIC IPC647E V25.02.12
  • Siemens SIMATIC IPC677E V25.02.12
  • Siemens SIMATIC IPC847E V25.02.12
  • Siemens SIMATIC ITP1000 V23.01.10
  • Siemens SIPLUS IPC427E V21.01.17

Exploit prediction

0.29% chance of exploitation in the next 30 days, higher than 21% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 8.2 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
NVD 2.0 7.2 AV:L/AC:L/Au:N/C:C/I:C/A:C

Affected products

  • Siemens RUGGEDCOM APE1808 - BIOS
  • Siemens SIMATIC Field PG M5
  • Siemens SIMATIC Field PG M6
  • Siemens SIMATIC IPC127E
  • Siemens SIMATIC IPC227G
  • Siemens SIMATIC IPC277G
  • Siemens SIMATIC IPC277G PRO
  • Siemens SIMATIC IPC327G
  • Siemens SIMATIC IPC377G
  • Siemens SIMATIC IPC427E
  • Siemens SIMATIC IPC477E
  • Siemens SIMATIC IPC477E PRO
  • Siemens SIMATIC IPC627E
  • Siemens SIMATIC IPC647E
  • Siemens SIMATIC IPC677E
  • Siemens SIMATIC IPC847E
  • Siemens SIMATIC ITP1000
  • Siemens SIPLUS IPC427E

Classification

Weakness

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.