Skip to content
Fencer Vulns
high 7.5

CVE-2021-43522 json

An issue was discovered in Insyde InsydeH2O with kernel 5.1 through 2021-11-08, 5.2 through 2021-11-08, and 5.3 through 2021-11-08.

published 2022-02-02 4 y ago modified 2026-08-11 2 mo ago also EUVD-2021-30451

cvss
7.5
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 18%
public exploits
0
none known

Summary

An issue was discovered in Insyde InsydeH2O with kernel 5.1 through 2021-11-08, 5.2 through 2021-11-08, and 5.3 through 2021-11-08. A StorageSecurityCommandDxe SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Patch / fix

  • Siemens RUGGEDCOM APE1808 - BIOS V1.0.202N
  • Siemens SIMATIC Field PG M5 V22.01.10
  • Siemens SIMATIC Field PG M6 V26.01.13
  • Siemens SIMATIC IPC127E V27.01.09
  • Siemens SIMATIC IPC227G V28.01.04
  • Siemens SIMATIC IPC277G V28.01.04
  • Siemens SIMATIC IPC277G PRO V28.01.04
  • Siemens SIMATIC IPC327G V28.01.04
  • Siemens SIMATIC IPC377G V28.01.04
  • Siemens SIMATIC IPC427E V21.01.17
  • Siemens SIMATIC IPC477E V21.01.17
  • Siemens SIMATIC IPC477E PRO V21.01.17
  • Siemens SIMATIC IPC627E V25.02.12
  • Siemens SIMATIC IPC647E V25.02.12
  • Siemens SIMATIC IPC677E V25.02.12
  • Siemens SIMATIC IPC847E V25.02.12
  • Siemens SIMATIC ITP1000 V23.01.10
  • Siemens SIPLUS IPC427E V21.01.17

Exploit prediction

0.26% chance of exploitation in the next 30 days, higher than 18% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 7.5 CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
NVD 2.0 6.9 AV:L/AC:M/Au:N/C:C/I:C/A:C

Affected products

  • Siemens RUGGEDCOM APE1808 - BIOS
  • Siemens SIMATIC Field PG M5
  • Siemens SIMATIC Field PG M6
  • Siemens SIMATIC IPC127E
  • Siemens SIMATIC IPC227G
  • Siemens SIMATIC IPC277G
  • Siemens SIMATIC IPC277G PRO
  • Siemens SIMATIC IPC327G
  • Siemens SIMATIC IPC377G
  • Siemens SIMATIC IPC427E
  • Siemens SIMATIC IPC477E
  • Siemens SIMATIC IPC477E PRO
  • Siemens SIMATIC IPC627E
  • Siemens SIMATIC IPC647E
  • Siemens SIMATIC IPC677E
  • Siemens SIMATIC IPC847E
  • Siemens SIMATIC ITP1000
  • Siemens SIPLUS IPC427E

Classification

Weakness

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.