CVE-2021-25677 json

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions…

published 2021-04-22 5 y ago modified 2026-06-17 4 mo ago also EUVD-2021-12569

cvss
5.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.1%
EPSS 1.1% chance of exploitation in 30 days, percentile 64%
public exploits
0
none known

Summary

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.

Patch / fix

  • siemens nucleus_readystart_v3 2017.02.4
  • siemens nucleus_readystart_v4 4.1.0

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-21-103-13 updated cvss 5.3

Siemens SIMOTICS CONNECT 400 (Update A)

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa ICSA-22-349-16 updated cvss 5.3

Siemens APOGEE and TALON

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

Exploit prediction

1.06% chance of exploitation in the next 30 days, higher than 64% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C
CNA 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
NVD 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:N/I:P/A:N

Affected products

  • Siemens APOGEE PXC Compact (BACnet)
  • Siemens APOGEE PXC Compact (P2 Ethernet)
  • Siemens APOGEE PXC Modular (BACnet)
  • Siemens APOGEE PXC Modular (P2 Ethernet)
  • Siemens Nucleus NET
  • Siemens Nucleus ReadyStart V3
  • Siemens Nucleus ReadyStart V4
  • Siemens Nucleus Source Code
  • Siemens SIMOTICS CONNECT 400
  • Siemens TALON TC Compact (BACnet)
  • Siemens TALON TC Modular (BACnet)

Classification

Weakness
  • CWE-330 Use of Insufficiently Random Values