Skip to content
Fencer Vulns
critical 9.8

CVE-2021-25274 in the critical feed json

The Collector Service in SolarWinds Orion Platform before 2020.2.4 uses MSMQ (Microsoft Message Queue) and doesn't set permissions on its p…

published 2021-02-03 5 y ago modified 2026-06-17 4 mo ago also EUVD-2021-12185

cvss
9.8
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
36.4%
EPSS 36.4% chance of exploitation in 30 days, percentile 98%
public exploits
0
none known

Summary

The Collector Service in SolarWinds Orion Platform before 2020.2.4 uses MSMQ (Microsoft Message Queue) and doesn't set permissions on its private queues. As a result, remote unauthenticated clients can send messages to TCP port 1801 that the Collector Service will process. Additionally, upon processing of such messages, the service deserializes them in insecure manner, allowing remote arbitrary code execution as LocalSystem.

Patch / fix

  • solarwinds orion_platform 2020.2.4

Exploit prediction

36.43% chance of exploitation in the next 30 days, higher than 98% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • trustwave.com https://www.trustwave.com/en-us/resources/blogs/spiderlabs-blog/full-system-control-with-new-solarwinds-orion-based-and-serv-u-ftp-vulnerabilities/ referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
NVD 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C

Classification

Weakness
  • CWE-502 Deserialization of Untrusted Data

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.