CVE-2021-22779 json
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versio…
published 2021-07-14 5 y ago modified 2026-06-17 4 mo ago also EUVD-2021-9914
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.1%
- EPSS 1.1% chance of exploitation in 30 days, percentile 64%
- public exploits
- 0
- none known
Summary
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
Patch / fix
- schneider-electric ecostruxure_control_expert 15.0
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-21-194-02 updated cvss 9.8
Schneider Electric Modicon Controllers and Software (Update A)
-
Schneider Electric Software, LLC EcoStruxure Control Expert 15.0 SP1, < 15.0 SP1 Schneider Electric Software, LLC EcoStruxure Process Expert Schneider Electric Software, LLC Modicon M340 CPU (part numbers BMXP34*) Schneider Electric Software, LLC Modicon M580 CPU (part numbers BMEP* and BMEH*) Schneider Electric Software, LLC SCADAPack RemoteConnect for x70affected: mitigation
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 5 mo ago
Exploit prediction
1.05% chance of exploitation in the next 30 days, higher than 64% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N |
| NVD | 3.1 | 9.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N |
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N |
| NVD | 2.0 | 6.4 | AV:N/AC:L/Au:N/C:P/I:P/A:N |
Affected products
- n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
Classification
- Weakness
-
- CWE-290 Authentication Bypass by Spoofing
References
Sources
- CVE List CVE-2021-22779
- NVD CVE-2021-22779
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.