Skip to content
Fencer Vulns
high 7.3

CVE-2021-0235 json

Junos OS: SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series: In a multi-tenant environment, a tenant host administrator may configure logical firewall isolation affecting other tenant networks

published 2021-04-22 5 y ago modified 2026-06-17 4 mo ago also EUVD-2021-2854

cvss
7.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 14%
public exploits
0
none known

Summary

On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series devices using tenant services on Juniper Networks Junos OS, due to incorrect permission scheme assigned to tenant system administrators, a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant. This issue affects: Juniper Networks Junos OS 18.3 version 18.3R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2; 18.4 version 18.4R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.1 versions 19.1R1 and later versions on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.3 versions prior to 19.3R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3; 20.1 versions prior to 20.1R2, 20.1R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.2 versions prior to 20.2R2-S1, 20.2R3 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.3 versions prior to 20.3R1-S2, 20.3R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series; 20.4 versions prior to 20.4R1, 20.4R2 on SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3 vSRX Series. This issue does not affect Juniper Networks Junos OS versions prior to 18.3R1.

Patch / fix

  • Juniper Networks Junos OS 19.2R1-S6, 19.2R3-S2, 19.3R3-S2, 19.4R2-S4, 19.4R3-S2, 20.1R2, 20.1R3, 20.2R2-S1, 20.2R3, 20.3R1-S2, 20.3R2, 20.4R1, 20.4R2

Exploit prediction

0.24% chance of exploitation in the next 30 days, higher than 14% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.3 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:L
NVD 2.0 4.6 AV:L/AC:L/Au:N/C:P/I:P/A:P

Affected products

  • Juniper Networks Junos OS

Classification

Weakness
  • CWE-276 Incorrect Default Permissions

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.