Skip to content
Fencer Vulns
high 8.6

CVE-2021-0203 json

Junos OS: EX and QFX5K Series: Storm Control does not work as expected when Redundant Trunk Group is configured

published 2021-01-15 5 y ago modified 2026-06-17 4 mo ago also EUVD-2021-2822

cvss
8.6
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.0%
EPSS 1.0% chance of exploitation in 30 days, percentile 63%
public exploits
0
none known

Summary

On Juniper Networks EX and QFX5K Series platforms configured with Redundant Trunk Group (RTG), Storm Control profile applied on the RTG interface might not take affect when it reaches the threshold condition. Storm Control enables the device to monitor traffic levels and to drop broadcast, multicast, and unknown unicast packets when a specified traffic level is exceeded, thus preventing packets from proliferating and degrading the LAN. Note: this issue does not affect EX2200, EX3300, EX4200, and EX9200 Series. This issue affects Juniper Networks Junos OS on EX Series and QFX5K Series: 15.1 versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R2-S5, 18.4R3-S3; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R2-S1, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2.

Patch / fix

  • Juniper Networks Junos OS 15.1R7-S7, 16.1R7-S8, 17.2R3-S4, 17.3R3-S8, 17.4R2-S11, 17.4R3-S2, 18.1R3-S10, 18.2R3-S5, 18.3R2-S4, 18.3R3-S2, 18.4R2-S5, 18.4R3-S3, 19.1R2-S2, 19.1R3-S2, 19.2R1-S5, 19.2R2-S1, 19.2R3, 19.3R2-S4, 19.3R3, 19.4R1-S3, 19.4R2-S1, 19.4R3, 20.1R1-S2, 20.1R2

Exploit prediction

1.01% chance of exploitation in the next 30 days, higher than 63% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 8.6 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
NVD 2.0 4.3 AV:N/AC:M/Au:N/C:N/I:N/A:P

Affected products

  • Juniper Networks Junos OS

Classification

Weakness
  • CWE-794 Incomplete Filtering of Multiple Instances of Special Elements

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.