Skip to content
Fencer Vulns
medium 5.8

CVE-2020-7381 json

Code Injection in Rapid7 Nexpose Installer

published 2020-09-03 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-28508

cvss
5.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.7%
EPSS 0.7% chance of exploitation in 30 days, percentile 52%
public exploits
0
none known

Summary

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Patch / fix

  • Rapid7 Nexpose 6.6.40

Exploit prediction

0.68% chance of exploitation in the next 30 days, higher than 52% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 5.8 CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L
NVD 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVD 2.0 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P

Affected products

  • Rapid7 Nexpose

Classification

Weakness
  • CWE-94 Improper Control of Generation of Code

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.