low 3.3

CVE-2020-6980 json

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all version…

published 2020-03-16 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-28120

cvss
3.3
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 36%
public exploits
0
none known

Summary

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-20-070-06 updated cvss 4.0

Rockwell Automation MicroLogix Controllers and RSLogix 500 Software

  • Rockwell Automation MicroLogix 1100 Controller Rockwell Automation RSLogix 500 Software <= 12.001 Rockwell Automation Series A Rockwell Automation Series B <= 21.001
    affected: mitigation “For MicroLogix 1400 series B controllers, Rockwell recommends affected users apply FRN 21.002 or later for MicroLogix 1400 Series B devices and use the enhanced password security feature.” compatibility.rockwellautomation.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Exploit prediction

0.41% chance of exploitation in the next 30 days, higher than 36% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 3.3 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
NVD 2.0 2.1 AV:L/AC:L/Au:N/C:P/I:N/A:N

Affected products

  • n/a Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior

Classification

Weakness
  • CWE-312 Cleartext Storage of Sensitive Information