CVE-2020-28391 json
A vulnerability has been identified in SCALANCE X-200 switch family (incl.
published 2021-01-12 5 y ago modified 2026-06-17 4 mo ago also EUVD-2020-20850
- cvss
- 5.9
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.1%
- EPSS 1.1% chance of exploitation in 30 days, percentile 66%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Patch / fix
- siemens scalance_x200-4pirt_firmware 5.5.0
- siemens scalance_x201-3pirt_firmware 5.5.0
- siemens scalance_x202-2irt_firmware 5.5.0
- siemens scalance_x202-2pirt_firmware 5.5.0
- siemens scalance_x202-2pirt_siplus_net_firmware 5.5.0
- siemens scalance_x204irt_firmware 5.5.0
- siemens scalance_xb205-3_firmware 5.2.5
- siemens scalance_xb205-3ld_firmware 5.2.5
- siemens scalance_xb208_firmware 5.2.5
- siemens scalance_xb213-3_firmware 5.2.5
- siemens scalance_xb213-3ld_firmware 5.2.5
- siemens scalance_xb216_firmware 5.2.5
- siemens scalance_xc206-2_firmware 5.2.5
- siemens scalance_xc206-2g_poe__firmware 5.2.5
- siemens scalance_xc206-2g_poe_eec_firmware 5.2.5
- siemens scalance_xc206-2sfp_firmware 5.2.5
- siemens scalance_xc206-2sfp_eec_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_(e/ip)_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_eec_firmware 5.2.5
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-21-012-02 updated cvss 9.1
Siemens SCALANCE X Switches (Update B)
-
Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) <V5.2.5affected: fixed in V5.2.5, mitigation support.industry.siemens.com
-
Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) <V5.5.0affected: fixed in V5.5.0, mitigation support.industry.siemens.com
-
Siemens SCALANCE X-200RNA switch family <V3.2.7affected: fixed in V3.2.7, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
1.13% chance of exploitation in the next 30 days, higher than 66% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 5.9 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N |
| NVD | 2.0 | 4.3 | AV:N/AC:M/Au:N/C:P/I:N/A:N |
Affected products
- Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
- Siemens SCALANCE X-200RNA switch family
Classification
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-274900.pdf
vendor-advisory
-
us-cert.cisa.gov
/ics/advisories/icsa-21-012-02
third-party-advisory, us-government-resource, vendor-advisory
Sources
- CVE List CVE-2020-28391
- NVD CVE-2020-28391
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.