Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input

published 2020-09-11 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-8186

cvss
4.3
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 20%
public exploits
0
none known

Summary

In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSMA-20-254-01 updated cvss 3.5

Philips Patient Monitoring Devices (Update C)

  • Philips IntelliVue patient monitor MP2-MP90 <=N Philips IntelliVue patient monitor MX100 <=N Philips IntelliVue patient monitor MX400-MX850 <=N
    affected: vendor fix, mitigation “Philips released the following versions to remediate reported vulnerabilities:” usa.philips.com
  • Philips IntelliVue X2 <=N Philips IntelliVue X3 <=N
    affected: mitigation “Philips released the following versions to remediate reported vulnerabilities:” incenter.medical.philips.com
  • Philips Patient Information Center iX (PICiX) B.02, C.02, C.03 Philips PerformanceBridge Focal Point A.01
    affected: vendor fix, mitigation “Philips released the following versions to remediate reported vulnerabilities:” incenter.medical.philips.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Exploit prediction

0.28% chance of exploitation in the next 30 days, higher than 20% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 4.3 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
NVD 2.0 3.3 AV:A/AC:L/Au:N/C:N/I:N/A:P

Affected products

  • Philips Patient Information Center iX (PICiX)
  • Philips PerformanceBridge Focal Point

Classification

Weakness
  • CWE-1286 Improper Validation of Syntactic Correctness of Input