Skip to content
Fencer Vulns
medium 6.8

CVE-2020-12149 json

OS Command Injection - Management File Upload

published 2020-12-11 5 y ago modified 2026-06-17 4 mo ago also EUVD-2020-4464

cvss
6.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.3%
EPSS 1.3% chance of exploitation in 30 days, percentile 71%
public exploits
0
none known

Summary

The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.

Patch / fix

  • arubanetworks edgeconnect_enterprise 8.1.9.15, 8.3.0.8, 8.3.1.2, 9.0.2.0

Exploit prediction

1.33% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 6.8 CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
NVD 3.1 6.8 CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
NVD 2.0 8.5 AV:N/AC:M/Au:S/C:C/I:C/A:C

Affected products

  • Silver Peak Systems, Inc. ECOS

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.