Skip to content
Fencer Vulns
high 8.2

CVE-2020-12034 json

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00,…

published 2020-05-20 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-4350

cvss
8.2
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
1.3%
EPSS 1.3% chance of exploitation in 30 days, percentile 69%
public exploits
0
none known

Summary

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.

Patch / fix

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-20-140-01 updated cvss 8.2

Rockwell Automation EDS Subsystem

  • Rockwell Automation FactoryTalk Linx software (Previously called RSLinx Enterprise) 6.00, 6.10, 6.11 Rockwell Automation RSLinx Classic <= 4.11.00 Rockwell Automation RSNetWorx software <= 28.00.00 Rockwell Automation Studio 5000 Logix Designer software <= 32
    affected: mitigation “Apply patch by following the instructions in knowledgebase article RAid 1125928 (login required).” rockwellautomation.custhelp.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Exploit prediction

1.26% chance of exploitation in the next 30 days, higher than 69% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 8.2 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H
NVD 2.0 4.8 AV:A/AC:L/Au:N/C:N/I:P/A:P

Affected products

  • n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software

Classification

Weakness
  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.