Skip to content
Fencer Vulns
medium 4.3

CVE-2020-11922 json

An issue was discovered in WiZ Colors A60 1.14.0.

published 2021-04-02 5 y ago modified 2026-06-17 4 mo ago also EUVD-2020-4259

cvss
4.3
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
1.1%
EPSS 1.1% chance of exploitation in 30 days, percentile 66%
public exploits
0
none known

Summary

An issue was discovered in WiZ Colors A60 1.14.0. The device sends unnecessary information to the cloud controller server. Although this information is sent encrypted and has low risk in isolation, it decreases the privacy of the end user. The information sent includes the local IP address being used and the SSID of the Wi-Fi network the device is connected to. (Various resources such as wigle.net can be use for mapping of SSIDs to physical locations.)

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
2 y ago

Exploit prediction

1.12% chance of exploitation in the next 30 days, higher than 66% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • eurofins-cybersecurity.com https://www.eurofins-cybersecurity.com/news/connected-devices-wiz-smart-lightbulbs/ referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
NVD 3.1 4.3 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
NVD 2.0 3.3 AV:A/AC:L/Au:N/C:P/I:N/A:N

Classification

Weakness
  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.