CVE-2020-10056 json
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4).
published 2020-09-09 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-2521
- cvss
- 7.8
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 30%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges.
Patch / fix
- siemens license_management_utility 2.4
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-252-03 updated cvss 7.8
Siemens License Management Utility
-
Siemens License Management Utility (LMU) <V2.4affected: fixed in V2.4, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
0.37% chance of exploitation in the next 30 days, higher than 30% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.2 | AV:L/AC:L/Au:N/C:C/I:C/A:C |
Affected products
- Siemens AG License Management Utility (LMU)
Classification
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-709003.pdf
vendor-advisory
-
us-cert.cisa.gov
/ics/advisories/icsa-20-252-03
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2020-10056
- NVD CVE-2020-10056