Skip to content
Fencer Vulns
medium 5.5

CVE-2019-7309 json

In the GNU C Library (aka glibc or libc6) through 2.29, the memcmp function for the x32 architecture can incorrectly return zero (indicatin…

published 2019-02-03 7 y ago modified 2026-10-14 25 d ago also EUVD-2019-16853

cvss
5.5
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.6%
EPSS 0.6% chance of exploitation in 30 days, percentile 49%
public exploits
0
none known

Summary

In the GNU C Library (aka glibc or libc6) through 2.29, the memcmp function for the x32 architecture can incorrectly return zero (indicating that the inputs are equal) because the RDX most significant bit is mishandled.

Patch / fix

  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP V3.1.5
  • Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP V3.1.5
  • Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP V3.1.5
  • glibc Debian 14, Debian 13, Debian 12 2.28-6

debian advisories DEBIAN-CVE-2019-7309

  • glibc openSUSE Tumbleweed 2.34-1.2

opensuse advisories openSUSE-SU-2024:10792-1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

red hat product security vex CVE-2019-7309 updated cvss 3.3

glibc: memcmp function incorrectly returns zero

  • Red Hat Enterprise Linux 5 glibc Red Hat Enterprise Linux 6 nscd, glibc, glibc-utils, glibc-common Red Hat Enterprise Linux 7 nscd, glibc, glibc-utils, glibc-common Red Hat Enterprise Linux 8 nscd, glibc, libnsl, nss_db, nss_hesiod, glibc-utils, +7 more
    not affected: vulnerable code not present

Red Hat CSAF VEX © Red Hat, Inc., from https://security.access.redhat.com/data/csaf/v2/vex/; changed: reduced to product statuses and remediations. CC BY 4.0 · csaf

cisa ICSA-23-348-10 updated cvss 5.5

Siemens SIMATIC S7-1500

  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) >= 3.1.0, < 3.1.5 Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) >= 3.1.0, < 3.1.5 Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) >= 3.1.0, < 3.1.5 Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) >= 3.1.0, < 3.1.5 Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) >= 3.1.0, < 3.1.5
    affected: fixed in V3.1.5, mitigation support.industry.siemens.com

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

Exploit prediction

0.61% chance of exploitation in the next 30 days, higher than 49% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • sourceware.org https://sourceware.org/bugzilla/show_bug.cgi?id=24155 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
NVD 3.0 5.5 CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
NVD 2.0 2.1 AV:L/AC:L/Au:N/C:N/I:N/A:P

Affected products

  • Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP
  • Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP
  • Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.