Skip to content
Fencer Vulns
medium 6.5

CVE-2019-6576 json

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Pan…

published 2019-05-14 7 y ago modified 2026-06-17 4 mo ago also EUVD-2019-16135

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.8%
EPSS 1.8% chance of exploitation in 30 days, percentile 78%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.

Patch / fix

  • siemens simatic_wincc_(tia_portal) 15.1
  • siemens simatic_wincc_runtime 15.1
  • siemens simatic_hmi_comfort_panels_firmware 15.1
  • siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
  • siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
  • siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
  • siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
  • siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
  • siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
5 mo ago

Exploit prediction

1.78% chance of exploitation in the next 30 days, higher than 78% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CISA ADP 3.1 6.5 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CNA 3.1 6.5 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
NVD 3.0 7.5 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N

Affected products

  • Siemens AG SIMATIC HMI Comfort Panels 4" - 22"
  • Siemens AG SIMATIC HMI Comfort Outdoor Panels 7" & 15"
  • Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F
  • Siemens AG SIMATIC WinCC Runtime Advanced
  • Siemens AG SIMATIC WinCC Runtime Professional
  • Siemens AG SIMATIC WinCC (TIA Portal)
  • Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)

Classification

Weakness

References

Sources