CVE-2019-6569 json
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network.
published 2019-03-26 7 y ago modified 2026-06-17 4 mo ago also EUVD-2019-16128
- cvss
- 9.1
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.3%
- EPSS 1.3% chance of exploitation in 30 days, percentile 71%
- public exploits
- 0
- none known
Summary
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Patch / fix
- siemens scalance_x-200_firmware 5.2.4
- siemens scalance_x-300_firmware 4.1.3
- siemens scalance_xp-200_firmware 4.1
- siemens scalance_xc-200_firmware 4.1
- siemens scalance_xf-200_firmware 4.1
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-19-085-01 updated cvss 5.4
Siemens SCALANCE X (Update D)
-
Siemens SCALANCE X204-2 <V5.2.6 Siemens SCALANCE X204-2FM <V5.2.6 Siemens SCALANCE X204-2LD <V5.2.6 Siemens SCALANCE X204-2LD TS <V5.2.6 Siemens SCALANCE X204-2TS <V5.2.6 Siemens SCALANCE X206-1 <V5.2.6affected: fixed in V5.2.6, mitigation support.industry.siemens.com
+7 more productsfewer
Siemens SCALANCE X206-1LD <V5.2.6 Siemens SCALANCE X208 <V5.2.6 Siemens SCALANCE X208PRO <V5.2.6 Siemens SCALANCE X212-2 <V5.2.6 Siemens SCALANCE X212-2LD <V5.2.6 Siemens SCALANCE X216 <V5.2.6 Siemens SCALANCE X224 <V5.2.6 -
Siemens SCALANCE X302-7 EEC (2x 24V, coated) <V4.1.3 Siemens SCALANCE X302-7 EEC (2x 24V) <V4.1.3 Siemens SCALANCE X302-7 EEC (2x 230V, coated) <V4.1.3 Siemens SCALANCE X302-7 EEC (2x 230V) <V4.1.3 Siemens SCALANCE X302-7 EEC (24V, coated) <V4.1.3 Siemens SCALANCE X302-7 EEC (24V) <V4.1.3affected: fixed in V4.1.3, mitigation support.industry.siemens.com
+21 more productsfewer
Siemens SCALANCE X302-7 EEC (230V, coated) <V4.1.3 Siemens SCALANCE X302-7 EEC (230V) <V4.1.3 Siemens SCALANCE X304-2FE <V4.1.3 Siemens SCALANCE X306-1LD FE <V4.1.3 Siemens SCALANCE X307-2 EEC (2x 24V, coated) <V4.1.3 Siemens SCALANCE X307-2 EEC (2x 24V) <V4.1.3 Siemens SCALANCE X307-2 EEC (2x 230V, coated) <V4.1.3 Siemens SCALANCE X307-2 EEC (2x 230V) <V4.1.3 Siemens SCALANCE X307-2 EEC (24V, coated) <V4.1.3 Siemens SCALANCE X307-2 EEC (24V) <V4.1.3 Siemens SCALANCE X307-2 EEC (230V, coated) <V4.1.3 Siemens SCALANCE X307-2 EEC (230V) <V4.1.3 Siemens SCALANCE X307-3 <V4.1.3 Siemens SCALANCE X307-3LD <V4.1.3 Siemens SCALANCE X308-2 <V4.1.3 Siemens SCALANCE X308-2LD <V4.1.3 Siemens SCALANCE X308-2LH <V4.1.3 Siemens SCALANCE X308-2LH+ <V4.1.3 Siemens SCALANCE X308-2M <V4.1.3 Siemens SCALANCE X308-2M PoE <V4.1.3 Siemens SCALANCE X308-2M TS <V4.1.3
76 more affected in the full advisory
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
1.33% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 9.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H |
| NVD | 2.0 | 6.4 | AV:N/AC:L/Au:N/C:P/I:N/A:P |
Affected products
- Siemens SCALANCE X204-2
- Siemens SCALANCE X204-2FM
- Siemens SCALANCE X204-2LD
- Siemens SCALANCE X204-2LD TS
- Siemens SCALANCE X204-2TS
- Siemens SCALANCE X206-1
- Siemens SCALANCE X206-1LD
- Siemens SCALANCE X208
- Siemens SCALANCE X208PRO
- Siemens SCALANCE X212-2
- Siemens SCALANCE X212-2LD
- Siemens SCALANCE X216
- Siemens SCALANCE X224
- Siemens SCALANCE X302-7 EEC (230V)
- Siemens SCALANCE X302-7 EEC (230V, coated)
- Siemens SCALANCE X302-7 EEC (24V)
- Siemens SCALANCE X302-7 EEC (24V, coated)
- Siemens SCALANCE X302-7 EEC (2x 230V)
- Siemens SCALANCE X302-7 EEC (2x 230V, coated)
- Siemens SCALANCE X302-7 EEC (2x 24V)
- Siemens SCALANCE X302-7 EEC (2x 24V, coated)
- Siemens SCALANCE X304-2FE
- Siemens SCALANCE X306-1LD FE
- Siemens SCALANCE X307-2 EEC (230V)
- Siemens SCALANCE X307-2 EEC (230V, coated)
- Siemens SCALANCE X307-2 EEC (24V)
- Siemens SCALANCE X307-2 EEC (24V, coated)
- Siemens SCALANCE X307-2 EEC (2x 230V)
- Siemens SCALANCE X307-2 EEC (2x 230V, coated)
- Siemens SCALANCE X307-2 EEC (2x 24V)
- Siemens SCALANCE X307-2 EEC (2x 24V, coated)
- Siemens SCALANCE X307-3
- Siemens SCALANCE X307-3LD
- Siemens SCALANCE X308-2
- Siemens SCALANCE X308-2LD
- Siemens SCALANCE X308-2LH
- Siemens SCALANCE X308-2LH+
- Siemens SCALANCE X308-2M
- Siemens SCALANCE X308-2M PoE
- Siemens SCALANCE X308-2M TS
- Siemens SCALANCE X310
- Siemens SCALANCE X310FE
- Siemens SCALANCE X320-1 FE
- Siemens SCALANCE X320-1-2LD FE
- Siemens SCALANCE X408-2
- Siemens SCALANCE XB205-3 (SC)
- Siemens SCALANCE XB205-3 (ST/BFOC)
- Siemens SCALANCE XB205-3LD
- Siemens SCALANCE XB208
- Siemens SCALANCE XB213-3 (SC)
Classification
- Weakness
-
- CWE-440 Expected Behavior Violation
References
-