CVE-2018-4858 json
A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configur…
published 2018-07-09 8 y ago modified 2026-06-17 4 mo ago also EUVD-2018-16644
- cvss
- 7.8
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.8%
- EPSS 1.8% chance of exploitation in 30 days, percentile 78%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
Patch / fix
- siemens sicam_pas/pqs 8.11
- siemens ec_61850_system_configurator_firmware 5.80
- siemens sicam_pq_analyzer_firmware 3.11
- siemens digsi_5_firmware 7.80
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-18-317-01 updated cvss 4.2
ICSA-18-317-01 Siemens IEC 61850 System Configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC
-
Siemens DIGSI 4 <V4.93affected: fixed in V4.93, mitigation support.industry.siemens.com
-
Siemens DIGSI 5 (affected as IEC 61850 system configurator is incorporated) <V7.80affected: fixed in V7.80, mitigation support.industry.siemens.com
-
Siemens IEC 61850 system configurator <V5.80affected: fixed in V5.80, mitigation support.industry.siemens.com
-
Siemens SICAM PAS/PQS <V8.11affected: fixed in V8.11, mitigation support.industry.siemens.com
-
Siemens SICAM PQ Analyzer <V3.11affected: fixed in V3.11, mitigation support.industry.siemens.com
-
Siemens SICAM SCC <V9.02_HF3affected: fixed in V9.02, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
1.81% chance of exploitation in the next 30 days, higher than 78% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 9.3 | AV:N/AC:M/Au:N/C:C/I:C/A:C |
Affected products
- Siemens AG IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC
Classification
- Weakness
-
- CWE-284 Improper Access Control
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-159860.pdf
vendor-advisory
-
securityfocus.com
/bid/105933
vdb-entry, third-party-advisory
-
ics-cert.us-cert.gov
/advisories/ICSA-18-317-01
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2018-4858
- NVD CVE-2018-4858