CVE-2018-11422 json
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confident…
published 2019-07-03 7 y ago modified 2026-06-17 4 mo ago also EUVD-2018-3453
- cvss
- 9.8
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.0%
- EPSS 1.0% chance of exploitation in 30 days, percentile 63%
- public exploits
- 0
- none known
Summary
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.
Exploit prediction
1.02% chance of exploitation in the next 30 days, higher than 63% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.5 | AV:N/AC:L/Au:N/C:P/I:P/A:P |
Classification
- Weakness
-
- CWE-319 Cleartext Transmission of Sensitive Information
References
-
github.com
/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md
third-party-advisory
Sources
- CVE List CVE-2018-11422
- NVD CVE-2018-11422
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.