CVE-2018-10594 in the critical feed json
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3,…
published 2018-06-26 8 y ago modified 2026-06-17 4 mo ago also EUVD-2018-2666
- cvss
- 9.8
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 68.3%
- EPSS 68.3% chance of exploitation in 30 days, percentile 99.3%
- public exploits
- 3
- Metasploit, Exploit-DB
Summary
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-18-172-01 updated cvss 7.3
Delta Electronics Delta Industrial Automation COMMGR
-
Delta Electronics AHSIM_5x0 AHSIM_5x0, AHSIM_5x1 Delta Electronics COMMGR <=1.08 Delta Electronics DVPSimulator EH2, EH3, ES2, SS2affected: mitigation “Delta Electronics has released COMMGR v1.09 to address this vulnerability and recommends users upgrade. The updated version can be downloaded at:”
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Timeline
- Published
- First public exploit (Metasploit exploit/windows/scada/delta_ia_commgr_bof)
Exploit prediction
68.27% chance of exploitation in the next 30 days, higher than 99.3% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- Metasploit exploit/windows/scada/delta_ia_commgr_bof Delta Electronics Delta Industrial Automation COMMGR 1.08 Stack Buffer Overflow metasploit exploit, normal rank, 2018-07-02
- EDB-45574 Delta Electronics Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (Metasploit) remote, 2018-10-09
- EDB-44965 Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (PoC) dos, 2018-07-02
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.5 | AV:N/AC:L/Au:N/C:P/I:P/A:P |
Affected products
- ICS-CERT Delta Industrial Automation COMMGR and accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1)
Classification
References
-
exploit-db.com
/exploits/44965/
exploit, third-party-advisory, vdb-entry
-
exploit-db.com
/exploits/45574/
exploit, third-party-advisory, vdb-entry
-
securityfocus.com
/bid/104529
vdb-entry, third-party-advisory
-
ics-cert.us-cert.gov
/advisories/ICSA-18-172-01
third-party-advisory, us-government-resource