Skip to content
Fencer Vulns
critical 9.8

CVE-2017-11402 json

An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00.

published 2017-11-20 8 y ago modified 2026-06-17 4 mo ago also EUVD-2017-3029

cvss
9.8
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
1.5%
EPSS 1.5% chance of exploitation in 30 days, percentile 75%
public exploits
0
none known

Summary

An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.

Exploit prediction

1.54% chance of exploitation in the next 30 days, higher than 75% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.0 9.8 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C

Classification

Weakness
  • CWE-20 Improper Input Validation

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.